Document Type : Review Article

Author

Department of Biotechnology, Faculty of Converging Sciences and Technologies, Islamic Azad University, Science and Research Branch, Tehran, Iran

Abstract

Introduction
Intelligent food packaging as a new technology can maintain the quality and safety of food during its shelf life. This technology uses indicators and sensors that are used in packaging and detects physiological changes in food (due to microbial and chemical degradation). These indicators usually provide information that can be easily identified by the food distributor and the consumer. However, most of the markers currently used are non-renewable and non-degradable synthetic materials. Microalgae that live in both marine and freshwater are a versatile solution for building new biosensors to detect pollutants such as herbicides or heavy metals. These photosynthetic microorganisms are very sensitive to their environmental changes and allow the detection of pollutants. In the past few years, several studies have been conducted in relation to the development, evaluation and application of biosensors using natural compounds in smart food packaging, and some of them are reported and summarized in Table 2.
 
Materials and Methods
In these studies, examples are mainly focused on biosensors related to biopolymers, but some other synthetic polymers that are easily degraded have also been used as examples. In Table 2, it is also specified what the function and application of the sensor is and how it reacts to the loss of freshness of food. Most sensors are sensitive to the change in pH caused by the release of volatile nitrogen compounds, and this change is characterized by a colorimetric response. Sensors are usually placed in the space above the food container, avoiding direct contact with the food, but close enough to detect changes in the environment and respond to changes in food quality. When these biosensors are integrated with biopolymers, they are usually incorporated into the polymer structure, and the color change of the layers (film) indicates changes in food quality in the packed product. The collected information also clearly shows that extracts rich in chemical compounds of pigments that change color with pH and especially anthocyanins have been used in these biosensors. In addition, most studies of biosensors have been conducted on fish, meat, and seafood, which is probably because their quality degradation is an important economic loss and also because the pH of the surrounding environment is changed during the degradation process. , and this change is easily detected through pH-sensitive biosensors. Smart food packaging technology has made it possible to monitor food quality by incorporating markers, sensors and radio frequency identification (RFID) into packaging. The technology also allows producers and consumers to trace the history of a product through important points in the food supply chain.Interestingly, some compounds applied and tested in the sensor not only provide a pH-sensitive dye, but also have other bioactive properties, for example, antimicrobial properties, and its presence in the polymer matrix can also increase the storage activity of packaging materials.
 
Results and Discussion
This paper shows that microalgae can be used as biosensors to detect pollutants such as herbicides, heavy metals and volatile organic compounds. These biosensors are very sensitive and reproducible for physical or chemical analysis. One of the main advantages of these microalgal biosensors is that repeated measurements can be performed without extensive sample preparation. They can also be selective, for example chlorophyll fluorescence emitted from photosynthetic activity allows the detection of herbicides, while inhibition of alkaline phosphatase and esterase allows the determination of heavy metals and organophosphate insecticides. Recently, great progress has been made in the identification of genes and related pathways in microalgae, and powerful techniques for genetic engineering have been developed. Collectively, the progress achieved in these areas will rapidly increase our ability to genetically optimize the production of more sensitive microalgae-based biosensors.

Keywords

Main Subjects

©2023 The author(s). This is an open access article distributed under Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source.

  1. Afreen, R., Tyagi, S., Singh, G.P., & Singh, M. (2021). Challenges and perspectives of polyhydroxyalkanoate production from microalgae/cyanobacteria and bacteria as microbial factories: an assessment of hybrid biological system. Frontiers in Bioengineering and Biotechnology, 9, 624885. https://doi.org/10.3389/fbioe.2021.624885
  2. Allouzi, M.M.A., Allouzi, S., Al-Salaheen, B., Khoo, K.S., Rajendran, S., Sankaran, R., & Show, P.L. (2022). Current advances and future trend of nanotechnology as microalgae-based biosensor. Biochemical Engineering Journal, 187, 108653. https://doi.org/10.1016/j.ecoenv.2012.01.002
  3. Altamirano, M., Garcıa-Villada, L., Agrelo, M., Sánchez-Martın, L., Martın-Otero, L., Flores-Moya, A., & Costas, E. (2004). A novel approach to improve specificity of algal biosensors using wild-type and resistant mutants: an application to detect TNT. Biosensors and bioelectronics, 19(10), 1319-1323. https://doi.org/10.1016/j.toxicon.2013.10.003
  4. Antonacci, A., & Scognamiglio, V. (2020). Biotechnological advances in the design of algae-based biosensors. Trends in Biotechnology, 38(3), 334-347. https://doi.org/3329/bjb.v42i2.18033
  5. Aydınoğlu, D. (2020). Active food packaging technology as an application in the food industry. Academic Studies in Engineering Sciences, 215. https://doi.org/21123/bsj.15.1.16-21
  6. Azman, N.H., Khairul, W.M., & Sarbon, N.M. (2022). A comprehensive review on biocompatible film sensor containing natural extract: Active/intelligent food packaging. Food Control, 141, 109189. https://doi.org/10.1016/j.foodcont.2022.109189
  7. Bao, Z., Weatherspoon, M. R., Shian, S., Cai, Y., Graham, P.D., Allan, S.M., & Kang, Z. (2007). Chemical reduction of three-dimensional silica micro-assemblies into microporous silicon replicas. Nature, 446(7132), 172-175. https://doi.org/10.1016/j.toxicon.2011.02.015
  8. Brayner, R., Couté, A., Livage, J., Perrette, C., & Sicard, C. (2011a). Micro-algal biosensors. Analytical and Bioanalytical Chemistry, 401, 581-597. https://doi.org/10.1016/j.aquatox.2015.11.002
  9. Brayner, R., Couté, A., Livage, J., Perrette, C., & Sicard, C. (2011b). Micro-algal biosensors. Analytical and Bioanalytical Chemistry, 401(2), 581-597. https://doi.org/10.1007/s00216-011-5107-z
  10. Carrilho, E.N.V., Nóbrega, J.A., & Gilbert, T.R. (2003). The use of silica-immobilized brown alga (Pilayella littoralis) for metal preconcentration and determination by inductively coupled plasma optical emission spectrometry. Talanta, 60(6), 1131-1140. https://doi.org/10.1016/j.toxicon.2007.09.001
  11. Chen, J., Ren, Y., Seow, J., Liu, T., Bang, W., & Yuk, H. (2012). Intervention technologies for ensuring microbiological safety of meat: current and future trends. Comprehensive Reviews in Food Science and Food Safety, 11(2), 119-132. https://doi.org/10.1016/j.algal.2014.12.009
  12. Chouteau, C., Dzyadevych, S., Chovelon, J.-M., & Durrieu, C. (2004). Development of novel conductometric biosensors based on immobilised whole cell Chlorella vulgaris Biosensors and Bioelectronics, 19(9), 1089-1096. https://doi.org/10.3390/md9112164
  13. Coste, M., Boutry, S., Tison-Rosebery, J., & Delmas, F. (2009). Improvements of the Biological Diatom Index (BDI): Description and efficiency of the new version (BDI-2006). Ecological Indicators, 9(4), 621-650. https://doi.org/10.1126/science.1099128
  14. De, P., & Mazumder, N. (2022a). Diatoms as sensors and their applications. In Diatom Microscopy (pp. 251-281). https://doi.org/10.1016/j.scitotenv.2019.03.104
  15. De, P., & Mazumder, N. (2022b). Diatoms as sensors and their applications. Diatom Microscopy, 251-281. https://doi.org/10.1016/j.hal.2015.10.015
  16. De Stefano, L., Rendina, I., De Stefano, M., Bismuto, A., & Maddalena, P. (2005a). Marine diatoms as optical chemical sensors. Applied Physics Letters, 87(23). https://doi.org/10.1111/pbi.12638
  17. De Stefano, L., Rendina, I., De Stefano, M., Bismuto, A., & Maddalena, P. (2005b). Marine diatoms as optical chemical sensors. Applied Physics Letters, 87(23), 233902. https://doi.org/10.3389/fmicb.2016.01693
  18. Durrieu, C., Badreddine, I., & Daix, C. (2003). A dialysis system with phytoplankton for monitoring chemical pollution in freshwater ecosystems by alkaline phosphatase assay. Journal of Applied Phycology, 15, 289-295. https://doi.org/10.1021/np500106w
  19. Durrieu, C., & Tran-Minh, C. (2002). Optical algal biosensor using alkaline phosphatase for determination of heavy metals. Ecotoxicology and Environmental Safety, 51(3), 206-209. https://doi.org/10.1016/j.hal.2010.12.002
  20. Ejeian, F., Etedali, P., Mansouri-Tehrani, H.-A., Soozanipour, A., Low, Z.-X., Asadnia, M., & Razmjou, A. (2018). Biosensors for wastewater monitoring: A review. Biosensors and Bioelectronics, 118, 66-79. https://doi.org/10.1016/j.bios.2018.07.019
  21. Giardi, M.T., & Pace, E. (2005). Photosynthetic proteins for technological applications. TRENDS in Biotechnology, 23(5), 257-263. https://doi.org/10.1016/j.febslet.2012.07.026
  22. Giere, O. (2008). Meiobenthology: the microscopic motile fauna of aquatic sediments: Springer Science & Business Media. https://doi.org/10.3390/toxins11110624
  23. Guedri, H., & Durrieu, C. (2008). A self-assembled monolayers based conductometric algal whole cell biosensor for water monitoring. Microchimica Acta, 163, 179-184. https://doi.org/10.1186/s40529-017-0211-9
  24. Halonen, N., Pálvölgyi, P.S., Bassani, A., Fiorentini, C., Nair, R., Spigno, G., & Kordas, K. (2020). Bio-based smart materials for food packaging and sensors – A Review. Frontiers in Materials, 7. https://doi.org/10.3389/fmats.2020.00082
  25. Hemavathi, A., & Siddaramaiah, H. (2018). Food packaging: polimers as packaging materials in food supply chains. Encyclopedia of polymer applications. CRC Press Boca Raton, 1374-1397. https://doi.org/10.1080/03650340.2010.499902
  26. Ladero, V., Calles-Enríquez, M., Fernández, M., & A Alvarez, M. (2010). Toxicological effects of dietary biogenic amines. Current Nutrition & Food Science, 6(2), 145-156. https://doi.org/10.3390/md11103689
  27. Lin, K.-C., Kunduru, V., Bothara, M., Rege, K., Prasad, S., & Ramakrishna, B. (2010). Biogenic nanoporous silica-based sensor for enhanced electrochemical detection of cardiovascular biomarkers proteins. Biosensors and Bioelectronics, 25(10), 2336-2342. https://doi.org/10.1007/s11104-008-9734-x
  28. Liu, Q., & Wang, P. (2009). Cell-based biosensors: principles and applications: Artech House. https://doi.org/10.1016/j.jplph.2010.09.013
  29. Mallick, N. (2002). Biotechnological potential of immobilized algae for wastewater N, P and metal removal: a review. Biometals, 15, 377-390. https://doi.org/10.1007/s11356-013-1535-y
  30. Mazumder, N., & Gordon, R. (2022). Diatom Microscopy: John Wiley & Sons. https://doi.org/10.3109/10408410902823705
  31. Monique, E. (2015). Volatile amines as criteria for chemical quality assessment. In. https://doi.org/10.1007/s11356-016-6223-2
  32. Moreno-Garrido, I. (2008). Microalgae immobilization: current techniques and uses. Bioresource Technology, 99(10), 3949-3964. https://doi.org/10.1016/S0041-0101(98)00114-7
  33. Nassif, N., & Livage, J. (2011). From diatoms to silica-based biohybrids. Chemical Society Reviews, 40(2), 849-859. https://doi.org/10.1006/abio.1995.1106
  34. Okuma, H., Okazaki, W., Usami, R., & Horikoshi, K. (2000). Development of the enzyme reactor system with an amperometric detection and application to estimation of the incipient stage of spoilage of chicken. Analytica Chimica Acta, 411(1-2), 37-43. https://doi.org/10.1016/j.foodchem.2012.01.107
  35. Park, Y.W., Kim, S.M., Lee, J.Y., & Jang, W. (2015). Application of biosensors in smart packaging. Molecular & Cellular Toxicology, 11, 277-285. https://doi.org/10.1007/BF01874863
  36. Pavelková, A. (2013). Time temperature indicators as devices intelligent packaging. Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis, 61(1), 245-251. https://doi.org/10.1016/j.ejsobi.2006.11.001
  37. Peña-Vázquez, E., Pérez-Conde, C., Costas, E., & Moreno-Bondi, M. (2010). Development of a microalgal PAM test method for Cu (II) in waters: comparison of using spectrofluorometry. Ecotoxicology, 19, 1059-1065. https://doi.org/10.4489/MYCO.2006.34.3.138
  38. Pospíšil, P. (2009). Production of reactive oxygen species by photosystem II. Biochimica et Biophysica Acta (BBA) - Bioenergetics, 1787(10), 1151-1160. https://doi.org/10.1016/j.bbabio.2009.05.005
  39. Poyatos-Racionero, E., Ros-Lis, J.V., Vivancos, J.-L., & Martínez-Máñez, R. (2018). Recent advances on intelligent packaging as tools to reduce food waste. Journal of Cleaner Production, 172, 3398-3409. https://doi.org/10.1016/j.jclepro.2017.11.075
  40. Punakivi, K., Smolander, M., Niku-Paavola, M.-L., Mattinen, J., & Buchert, J. (2006). Enzymatic determination of biogenic amines with transglutaminase. Talanta, 68(3), 1040-1045. https://doi.org/4489/MYCO.2008.36.4.242
  41. Purohit, B., Vernekar, P. R., Shetti, N. P., & Chandra, P. (2020). Biosensor nanoengineering: Design, operation, and implementation for biomolecular analysis. Sensors International, 1, 100040. https://doi.org/10.1016/j.algal.2016.04.004
  42. Rahman, M.A., Soumya, K., Tripathi, A., Sundaram, S., Singh, S., & Gupta, A. (2011). Evaluation and sensitivity of cyanobacteria, Nostoc muscorum and Synechococcus PCC 7942 for heavy metals stress–a step toward biosensor. Toxicological & Environmental Chemistry, 93(10), 1982-1990. https://doi.org/10.1016/j.scitotenv.2014.04.037
  43. Rathnayake, I., Munagamage, T., Pathirathne, A., & Megharaj, M. (2021). Whole cell microalgal-cyanobacterial array biosensor for monitoring Cd, Cr and Zn in aquatic systems. Water Science and Technology, 84(7), 1579-1593. https://doi.org/10.1139/W08-034.
  44. Reynolds, C.S. (2006). The ecology of phytoplankton: Cambridge University Press. https://doi.org/30493/DAS.2020.246624
  45. Roberta, B., Alain, C., Jacques, L., Catherine, P., & Clemence, S. (2011). Micro-algal biosensors. Analytical and Bioanalytical Chemistry, 401(2), 581-598. https://doi.org/30493/DAS.2020.246624.
  46. Rodriguez Jr, M., Sanders, C. A., & Greenbaum, E. (2002). Biosensors for rapid monitoring of primary-source drinking water using naturally occurring photosynthesis. Biosensors and Bioelectronics, 17(10), 843-849. https://doi.org/10.1111/jpy.120
  47. Sandhage, K. H., Allan, S. M., Dickerson, M. B., Gaddis, C. S., Shian, S., Weatherspoon, M. R., & Snyder, R. L. (2005). Merging biological self‐assembly with synthetic chemical tailoring: The Potential for 3‐D Genetically Engineered Micro/Nano‐Devices (3‐D GEMS). International Journal of Applied Ceramic Technology, 2(4), 317-326. https://doi.org/10.1007/s10295-010-0833-3
  48. Saraswati, P.K., & Srinivasan, M. (2015). Micropaleontology: Principles and applications: Springer. https://doi.org/3923/ajps.2003.944.951
  49. Shao, C., Howe, C., Porter, A.J.R., & Glover, L. (2002). Novel cyanobacterial biosensor for detection of herbicides. Applied and Environmental Microbiology, 68(10), 5026-5033. https://doi.org/10.1007/s10265-006-0057-9
  50. Shitanda, I., Takada, K., Sakai, Y., & Tatsuma, T. (2005). Compact amperometric algal biosensors for the evaluation of water toxicity. Analytica Chimica Acta, 530(2), 191-197. https://doi.org/10.1016/j.aquatox.2013.04.007
  51. Sobhan, A., Muthukumarappan, K., & Wei, L. (2021). Biosensors and biopolymer-based nanocomposites for smart food packaging: Challenges and opportunities. Food Packaging and Shelf Life, 30, 100745. https://doi.org/10.1016/j.fpsl.2021.100745
  52. Tajes-Martinez, P., Beceiro-Gonzalez, E., Muniategui-Lorenzo, S., & Prada-Rodriguez, D. (2006). Micro-columns packed with Chlorella vulgaris immobilised on silica gel for mercury speciation. Talanta, 68(5), 1489-1496. https://doi.org/10.1016/j.jgeb.2013.04.001.
  53. Védrine, C., Leclerc, J.-C., Durrieu, C., & Tran-Minh, C. (2003). Optical whole-cell biosensor using Chlorella vulgaris designed for monitoring herbicides. Biosensors and Bioelectronics, 18(4), 457-463. https://doi.org/10.1093/oxfordjournals.aob.a084742.
  54. Verma, N., Kaur, H., & Kumar, S. (2011). Whole cell based electrochemical biosensor for monitoring lead ions in milk. Biotechnology, 10(3), 259-266. https://doi.org/10.3390/app11020871
  55. Wadhera, T., Kakkar, D., Wadhwa, G., & Raj, B. (2019). Recent advances and progress in development of the field effect transistor biosensor: A review. Journal of Electronic Materials, 48, 7635-7646. https://doi.org/10.1007/s11099-017-0716-1
  56. Yam, K.L., Takhistov, P.T., & Miltz, J. (2005). Intelligent packaging: concepts and applications. Journal of Food Science, 70(1), R1-R10. https://doi.org/1007/s11274-019-2653-6
  57. Zamaleeva, A.I., Sharipova, I.R., Shamagsumova, R.V., Ivanov, A.N., Evtugyn, G.A., Ishmuchametova, D.G., & Fakhrullin, R.F. (2011). A whole-cell amperometric herbicide biosensor based on magnetically functionalised microalgae and screen-printed electrodes. Analytical Methods, 3(3), 509-513. https://doi.org/10.1016/j.fob.2011.10.004

 

 

CAPTCHA Image